ALL NECE CHECKS

NECE Anodizing  is particularly careful to the quality, also in terms of a global clientele. From the arrival of the material to the shipment of the product NECE performs well 18 checks.

MATERIAL ACCEPTANCE TO WAREHOUSE

UNPACKING AND MECHANICAL PRE-TREATMENT

HOOKING TO THE PLANT

ANODIC OXIDATION

1. External check of the items to verify their integrity and therefore that they haven’t damages
2. Verification of the total gross weight.

3. Numerical control and of the possible presence of defects on the material to be worked.

4. Check of the mechanically pre-treated surface.

5. Check opacity / brilliance of the chemically pre-treated surface.
6. Thickness measure of the anodic film.
7. Visual inspection of color fidelity.

LABORATORY

PACKING

LARGE ORDERS

ADMITTANCE MEASUREMENT

8. Parameters Control of chemical baths (concentration , pH and temperature) .
9. Drop test for the fixing quality*
10. Test of weight loss for the fixing quality (UNI EN 12373-7).*
11. Test of abrasion resistance (Clark Test / BS 6161).*
12. Visual inspection to check for any non-compliance (color , scratches, dents) .
13. Color check with Spectrophotometer.*
14. Brilliance check with Glossmeter.*
15. Anodic film thickness check with Micrometer.*
16. Thickness check of the anodic film with Micrometer.

17. On request and only for large orders, Anodizing NECE can also perform checks from raw of material hardness, size , thickness and flatness of the profiles.

18. Only on request and only on large orders, Admittance measurement test according to UNI EN ISO 2931.

* On request, with the issue of the ” Anodizing Treatment Certificate”.